Add to Cart
AC400V-300KW Adjustable Load Bank With Frequency 50HZ And Best Sales
Introduction
AC400-300KW Resistive Load Bank. The system accurately test output power and load capacity of all kinds of generators, main electrical parameters including the dynamic parameters tested.
Application
Technical specification
| Technical Parameters | |
| Rating Voltage/Frequency | AC 400V/50Hz, 3 phase 4 wire |
| Max Load Power | Resistive Load: 310kW |
| Load Step | Resistive Load:10 steps; 1, 2, 2, 5, 10, 20, 20, 50, 100,100kW |
| Power Factor | 1 |
| Load Tolerance(each step) | ±5% |
| Load Tolerance(overall) | ±3% |
| Display Precision | 0.5 class |
| Control Power Supply | Input400VAC 3 phase 4 wire 50hz |
| Wire Connection | Load Power Supply Input——Copper bar (star connection) Control power supply input——Connector bar |
| Communication Interface | RS485 (2), RS232 (1) |
| Insulation Class | F |
| Working Mode | Continuous Working |
| Cooling | Forced air cooling,Horizontal inlet air,Horizontal outlet |
| Transportation | Hoisting, there are lifting lug in top of case and wheel castors in bottom |
| Chassis color | Black&White(RAL7035) |
| Dimension | Approximately; 1250*1550*1680 (Width *Length *Height) |
| Operating Environment Parameter | |
| Ambient Temperature | -10℃~+50℃ |
| Relative Humidity | ≤95% |
| Altitude | ≤2500 meters |
| Atmospheric Pressure | 86~106kPa |
Communication pattern: Intelligent control use photoelectric isolated RS485 interface connect to PC, with great anti-interference performance to make system control stable. Also user can use USB or RS232 through converter.
Load pattern: Manual Load or Automatic Load.
Manual Load: Input power, system will load according to preset power.
--Automatic load: user can preset power and length of working time of several load periods, as per 0%→25%→50%→75%→100% or 110% to make testing.
Parallel testing: when several load bank work in parallel, use can make parallel testing via software, can display, record parameters of every load bank and whole system parameter of parallel operation.
--Real-time parameter: through software to display voltage, current, power, power factor, frequency and time, etc.
Security monitoring and control: monitor working state of the load bank by watching software light, when abnormally stop and protect, it can show the reason.
Data save and query: all the test data is saved in the software, easy to query in the history testing data.
Graphical display: show real-time or history testing data, and support to print curve and graph as follows:
1) Graphs of real-time voltage, current, frequency and power; 2) Voltage graph
3) Current graph; 4) Power graph; 5) Frequency graph; 6) Power factor graph
Data format: all the curves and graphs can be outputted as".doc"format, testing data can be outputted as ”.xls” format, and can be printed.