Hebei Kaixiang Electrical Technology Co., Ltd

Manufacturer from China
Active Member
7 Years
Home / Products / Reactive Load Bank /

600 KVAR High Power Reactive Load Bank , Grey Surface Inductive Load Bank

Contact Now
Hebei Kaixiang Electrical Technology Co., Ltd
City:shijiazhuang
Province/State:hebei
Country/Region:china
Contact Now

600 KVAR High Power Reactive Load Bank , Grey Surface Inductive Load Bank

Ask Latest Price
Video Channel
Brand Name :KaiXiang
Model Number :AC415/400-600KVAR
Certification :ISO9001-2008
Place of Origin :China
MOQ :1 set
Price :negotiable
Payment Terms :Western Union, L/C, T/T
Supply Ability :60 Set/Sets per Month
Delivery Time :Within 35 working days
Packaging Details :Packed in wooden cases
Max Load Power :AC415/400-600KVAR
Rated Voltage /Frequency :AC415/400
Colour :Grey surface
Total Tolerance :±3%
Communication Interface :RS485、RS232
Rated power :600KVAR
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

AC415/400-600KVAR Reactive Load Bank In Good Performance And Power Factor 0.8
Introduction

1 System mainly consists of resistance load, data collecting, control system, cooling device, etc. The system can test output power and load performance of generator sets.

2 System can load power in rated range, measure generator steady-state 3 phase voltage, current, active power, power factor, frequency, and running time, and simulate the generator set real load working state. Power input using sectional type, energy dissipation type load, forced-air cooling, 3 phase fan decentralized supply air, air-flow is sufficient and low noise.

3 The system is a self-developed device used for electricity load testing by Kaixiang Technology. It perfectly combines the high voltage dry type load module and measurement and control module, precisely test output power and load performance of kinds of generator set.

Applications

(1) Installation: Check installation environment , the machine should be placed in the open, flat, safe environment, the bottom four corners must be flat, sturdy sleepers paving to reduce vibration during operation, and improve the reliability of the ground.

(2) Ventilation inspection: Turn on all the ventilation doors of machine, including the top door and side door, and then fixed. Observe if all vents are normal, whether the foreign body obstruction, whether the surroundings neat and clean, near unit will not hinder ventilation debris, make sure the duct patency.

Technical Specifications

System Parameter
Rating voltage/frequency 415V/400V, 3 phase 4 wire 50Hz
Max Load Power Inductive Load: 600KVAR
Load Resolution

Total 645KVAR @415V 3 phase 4wire,50HZ

1KVAR,2 KVAR, 2KVAR, 5KVAR,5KVAR, 10KVAR, 10KVAR, 20KVAR, 20KVAR,20KVAR, 50KVAR, 100KVAR,200KVAR,200KVAR

Total 600KVAR @ 400V 3phase 4wire, 50HZ

0.93KVAR,1.86KVAR, 1.86KVAR, 4.65KVAR, 4.65KVAR,9.3KVAR, 9.3KVAR, 18.6KVAR, 18.6KVAR,18.6KVAR,46.5KVAR, 93KVAR,186KVAR,186KVAR

Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External AC 3 phase 4 line, 415V/50Hz
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP21
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, horizontal air outlet
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Operating Environment Parameter
Workplace Indoor or outdoor with canopy
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor Kaixiang
Data Processing Software Kaixiang
Main features

Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency. High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.

Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.
New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

Mature Manufacturing Technology: load element using excellent anti-corrosion materials; waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.

High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.

Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.

600 KVAR High Power Reactive Load Bank , Grey Surface Inductive Load Bank


Inquiry Cart 0