AC450V-1000KW 3 Phase Load Bank With Best Sales And High Performance
Introduction
AC450V-1000KW 3 Phase Load Bank consist of dry load module and auto control module, test load and output power of generators, the test including setting, fluctuation,transient load/unload,recorded wave analysis,harmonic analysis,testing the static parameter and dynamic parameter
(1) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.
(2) Local meter display data: 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency etc.
(3) Control mode: user can choose local control, remote control or intelligent control (PC control)
(4) Local manual control: local control panel in load bank, with multi load steps, controlled by buttons.
(5) Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph, also can be printed.
Technical specification
System Parameter | |
Rating voltage/frequency | 450VAC, 3 phase 4 wire, wire voltage 450V, phase voltage 260V 50HZ/60HZ When voltage lower than 450V, it will change according to Ohm’ law |
Max Load Power | Resistive Load: 1000kW |
Load Resolution | Resistive Load: 13 steps, 1kW,2KW,2kW,5kW,10kW,10kW,20kW,50kW,100kW, 200kW,200kW, 200kW,200kW |
Power Factor | 1 |
Load Tolerance (each step) | ±5% |
Load Tolerance (overall) | ±3% |
Fan &Control Voltage | External 400V 3 phase 4 wire, wire voltage: 400V, phase voltage: 230V, 50HZ |
Wire Connection | Load bank input——Copper bar (star coupling ”Y”) Control power input——Connector-bar |
Communication Interface | RS485,RS232 |
Insulation | F |
Max Protection Grade | IP54 |
Duty Cycle | Continuous |
Cooling | Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling |
Enclosure | Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door |
Internal Lighting | Adequate internal lighting will be provided |
Transportation | Hoisting, there are lifting lug in top of casing |
Color | Grey RAL7035 or as required |
Dimensions | About 3000mm*2350mm*2591mm(L×W×H) |
Operating Environment Parameter | |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Atmospheric Pressure | 86~106kPa |
Brands of Main Components | |
Contactor | Schneider |
Fuse | Miro |
PLC | Siemens |
Alloy Resistor | (self-developing) |
Data Processing Software | (self-developing) |
(1) Load mode: manual load or automatic load.
(2) Manual load: input power and power factor, then will load according to the value.
(3) Preset Load: input the parameter of generator, choice 0%,25%,50%,75%,100%,110%, calculate power value automatically,
(4) Step by Step Load: during steady state load, load bank will increase or reduce power so that smoothly transit into target power, avoiding unscheduled transient load/unload. Step value and step interval can be set.
(5) Constant Power Load: automatically adjust to the power when the voltage fluctuation, keep the setting value.
(6) Auto Load: power and time can be set to some stage, process stage test automatically. Allow pause or process next stage during loading.