Hebei Kaixiang Electrical Technology Co., Ltd

Manufacturer from China
Active Member
7 Years
Home / Products / 3 Phase Load Bank /

4500 KW Intelligent 3 Phase Load Bank , Local Manual Control AC Load Bank

Contact Now
Hebei Kaixiang Electrical Technology Co., Ltd
City:shijiazhuang
Province/State:hebei
Country/Region:china
Contact Now

4500 KW Intelligent 3 Phase Load Bank , Local Manual Control AC Load Bank

Ask Latest Price
Video Channel
Brand Name :Kaixiang
Model Number :AC450V - 4500KW
Certification :ISO9001
Place of Origin :China
MOQ :1 set
Price :negotiable
Payment Terms :Western Union
Supply Ability :90 Sets / Month
Delivery Time :Within 33 working days
Packaging Details :Packaged in container
Model :AC450 - 4500KW
Rated power :4500 KW
Voltage :AC450V
Colour :Grey
Performance :Continous working
Total tolerance :±3%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

AC450 - 4500KW 3 Phase Load Bank With Best Sales And High Performance

Introduction

AC450 - 4500KW 3 Phase Load Bank consist of dry load module and auto control module, test load and output power of generators, the test including setting, fluctuation,transient load/unload,recorded wave analysis,harmonic analysis,testing the static parameter and dynamic parameter

Applications
Application

(1) Intelligent control: user can control load bank by data processing software of PC to make automatic load/unload, display, record and manager the test data, form curve, graph, also can be printed.

(2) Control mode interlock: there is switch in control panel to choose control mode, other control mode is invalid if user choose one control mode.

(3) Local meter display data: 3 phase voltage, current, active power, reactive power, apparent power, power factor, frequency etc.

(4) Control mode: user can choose local control, remote control or intelligent control (PC control)

(5) Local manual control: local control panel in load bank, with multi load steps, controlled by buttons.

Technical specification

System parameters
Rated voltage AC three-phase three-wire 4 5 0V
Rated Power Purely resistive load 4500KW;
Power Factor 1 and 0.8 for each two
Resistive Binning 1KW × 1, 2KW × 2, 5KW × 1, 10KW × 2, 20KW × 1, 50KW × 1, 100KW × 2, 200KW × 21
Load accuracy ± 3%
Cold state change After long-term use of the load, the rate of resistance change ≤ ± 3%
Imbalance Resistance phase imbalance ≤ ± 3%
Display accuracy 0.5
Power Supply AC three-phase four-wire 380V/50Hz, with a phase sequence protection
Insulation class Class F
Insulation resistance ≥ 30MΩ
Resistor Installation Insulation made ​​of high-strength composite structure, the resistance of the insulation board is installed, the resistance and the overall chassis isolation.
Electromagnetic Compatibility Equipment is available in special measures are not taken shielded ordinary venue operation, electromagnetic compatibility compliance with the relevant standards, electromagnetic compatibility tests before leaving the factory.
Other parameters

Insulation resistance (resistance per unit): AC1500V, 50Hz, 1min not breakdown

Melting point: 1500 ℃ maximum working temperature 320 ℃

Control

Local automatic control (control via local control panel)

Intelligent Remote Control (via the remote controller is installed to control the data processing software)

(Or is controlled by data processing software installed on the laptop)

Each control can display cabinet work load status and alarm indication.

Remote Controller Computer packed aluminum box
Wiring Using copper wiring, each phase can be connected to 16 low voltage cable 1 × 240mm ²
Protection class IP5 5 (during storage)
Work Continuous work
Cooling Forced air, side air intake on the wind
Chassis construction Container type, with up to the top of the ladder
Transportation and seismic design Box using standard container design, bearing hanging hole, in line with lifting and transport conditions. Lifting points can be issued by non-destructive inspection reports, bearing more weight to the load box three times.
Illumination With internal lighting and power socket and put condensation heaters fitted
Inlet and outlet protection with vents Equipment cabinet inlet and outlet with a protective door, turn off the water. Optional protection on both sides of the vent doors, shutters can also choose to add stainless steel fence, to prevent the entry of foreign matter and other small animals.
Top waterproof design Around the outlet along the top of the chassis are waterproof, rain deflector can be, shed from a secure location to prevent the top of the water, is conducive to the chassis storage and use in continuous rainy weather.
Load box volume Approximately 6125mm × 2438mm × 2591mm (L × W × H)
Load box weight About 12000kg
Me change the volume Approximately 6125mm × 2438mm × 2591mm (L × W × H)
Me change the weight (0.8) About 22000kg
Me change the weight (1) About 15000kg
Box changes About 15000kg
Work environment parameters
Operating Temperature -10 ℃ ~ +50 ℃
Relative Humidity ≤ 95%
Altitude ≤2500 meters
Atmospheric pressure 86 ~ 106kPa
Seismic intensity 8 degrees
Main features

(1) Load mode: manual load or automatic load.

(2) Manual load: input power and power factor, then will load according to the value.

(3) Preset Load: input the parameter of generator, choice 0%,25%,50%,75%,100%,110%, calculate power value automatically,

(4) Auto Load: power and time can be set to some stage, process stage test automatically. Allow pause or process next stage during loading.

(5) Step by Step Load: during steady state load, load bank will increase or reduce power so that smoothly transit into target power, avoiding unscheduled transient load/unload. Step value and step interval can be set.

(6) Constant Power Load: automatically adjust to the power when the voltage fluctuation, keep the setting value.

4500 KW Intelligent 3 Phase Load Bank , Local Manual Control AC Load Bank

Inquiry Cart 0