Hebei Kaixiang Electrical Technology Co., Ltd

Manufacturer from China
Active Member
7 Years
Home / Products / 3 Phase Load Bank /

3 MW Resistive Load Bank Vertical Exhaust Cooling For Generator Load Test

Contact Now
Hebei Kaixiang Electrical Technology Co., Ltd
City:shijiazhuang
Province/State:hebei
Country/Region:china
Contact Now

3 MW Resistive Load Bank Vertical Exhaust Cooling For Generator Load Test

Ask Latest Price
Video Channel
Brand Name :Kaixiang
Model Number :AC440-3MW
Certification :ISO9001
Place of Origin :China
MOQ :1 set
Price :negotiable
Supply Ability :20 sets / month
Delivery Time :Within 30 working days
Packaging Details :Packaged in container
Model :AC440V-3MW
Rated power :3 MW
Voltage :AC440V
Colour :Grey
Performance :Continous working
Total tolerance :±3%
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

AC440-3MW 3 Phase Load Bank With High Performance And Best Sales

Introduction

According to the special requirements of users on site, in the agreement the technical standards of AC440-3MW Resistive Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator, UPS load test.

The system consists of 1 sets of 3MW Resistive load bank. The resistive power is 3MW. The System is made up of two parts of measurement and control and load, mainly including the outdoor type dry load, automatic data acquisition system, automatically loading and unloading control system, the cooling device, auxiliary control, remote controller and PC software and so on.

Applications

According to the special requirements of users on site, in the agreement the technical standards of AC440-3MW 3 Phase Load Bank (hereinafter referred to as "system") and its accessories are proposed including their function, performance, usage, structure, installation and test to provide users with a high efficient and reliable choice, in order to meet the need for generator load test.

Technical specification

System Parameter
Rating voltage/frequency 440V 3 phase 4 line,60HZ
Max Load Power Resistive Load: 3000kW
Load Resolution

Resistive Load: 23steps,

1kW,2kW,2kW,5kW,10kW,10kW,20kW,50kW,100kW,200kW*14

Power Factor 1
Load Tolerance (each step) ±5%
Load Tolerance (overall) ±3%
Fan &Control Voltage External 380V 3 phase 4 wire, 60HZ
Wire Connection

Load bank input——Copper bar (star coupling ”Y”)

Control power input——Connector-bar

Communication Interface RS485,RS232
Insulation F
Max Protection Grade IP54
Duty Cycle Continuous
Cooling Forced air cooling, by Axial Fan; horizontal inlet air, vertical exhaust cooling
Enclosure Container type,with a ladder, air inlet and outlet with mesh enclosure and protection door
Internal Lighting Adequate internal lighting will be provided
Transportation Hoisting, there are lifting lug in top of casing
Color Grey RAL7035 or as required
Dimensions About 6058mm*2350mm*2591mm(L×W×H)
Weight About 7000kgs
Operating Environment Parameter
Ambient Temperature -10℃~+50℃
Relative Humidity ≤95%
Atmospheric Pressure 86~106kPa
Brands of Main Components
Contactor Schneider
Fuse Miro
PLC Siemens
Alloy Resistor (self-developing)
Data Processing Software (self-developing)
Main features

Kaixiang Dummy Load Bank scientific and technology level is in leading position in this industry, besides general functions, it has following unique advantages:

Intelligent Loading: after setting generator rated power in software, system realize rapid loading through preset proportion, automatically and continuously load multiple power value and common tests, like stepping, full load, and over load, so that improve working efficiency.

High Efficiency Data Management: display real-time testing data, generate curves graphs automatically, also can put data into storage. According to generator set No. set up testing file, support to query at any time, and improve data management efficiency.

Comprehensive Protection Function: multiple protection, like over temperature, smoke. When in danger, automatically terminate the test and give alarm to protect safety of personnel and equipment.

Stable Running: with the latest generation control module as the core, a sharp rise in system response speed and anti-interference performance, avoid function failure in complex electrical environment, and ensure system running stably and reliably.

New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.

Standard Testing Function: System can do stable test, transient test, and realize functions, such as setting, fluctuation, instant load, and instant unload. The terms and formulas used in test strictly comply with relevant national standard.

High Power Load: high load power density, large capacity of single set, parallel running to finish super power testing, and realize tens of megawatts of power loading.

Accurate Data: with high precision data collection module and measuring meter, related equipment has passed the certification by CMA (China Metrology Accreditation) qualification testing institution, and ensures the reliability of data.

Flexible Control Mode: based on different using habit, several control modes as following can be choose, local panel operation, remote box controlling, and intelligent software.

3 MW Resistive Load Bank Vertical Exhaust Cooling For Generator Load Test

Inquiry Cart 0