Add to Cart
Full automatic 415V 670KVA Inductive Load Bank For Middle East
Product description
load banks are devices which contain resistive,inductive and/or capacitive loads,apply the load to an electrical power source and dissipate the power of the electrical source .unlike the on-site loads which are randomly variable in terms of many electrical parameters ,load banks provide predetermines and controllable load which serves power source usings energy output to test,support or protect the power source
Technical Parameter
Rating Voltage/Frequency | 415VAC/50Hz, 3 phase 4 wire, |
Voltage range | 380v 50hz ±10% |
Max Rated power | Apparent Power: 670kVA |
Load Resolution | Resistive Load: 0.1.0.2.0.2.0.5.1.2.2.5.10.20.20.50.100.100.100.100.100kw |
Load Tolerance (each step) | ±5% |
Load Tolerance(overall) | ±3% |
Display Precision | 0.5 class |
Control Power | 380VAC/50Hz, |
Wire Connection | Load power supply input——Copper bar (star coupling) |
Communication Interface | RS485, |
Casing Dimensions and Cooling | about 1460*1980*1800mm (length*width*height) Forced air cooling,Horizontal inlet air,Vertical cooling |
Weight | About 3500kgs/set |
Transportation | Hoisting, there are lifting lug in top of casing |
Casing Color | Grey(RAL7035) |
Ambient Temperature | -10℃~+50℃ |
Relative Humidity | ≤95% |
Altitude | ≤2500 meter |
Atmospheric Pressure | 86~106kPa |
Contactor | Schneider |
Fuse | DELIXI |
MCU | INFINEON |
Data processing software | Kaixiang(self-developed) |
Alloy Resistance | Kaixiang(self-developed) |
Product Advantage
1. New Load Bank Technology: using the international advanced AC load bank technology, overcome the old water bank defects, such as bear bumpy, unable to use when go to sea, realize Mooring Trial and Sea Trail, and simulate the real working condition of generator running.
2. Mature Manufacturing Technology: load element using excellent anti-corrosion materials, waterproof insulation container packaging, suitable for adverse environment such as ocean. Internal layout is reasonable, air channel is clear, rapid heat emission, and satisfy continuous working need.
Application
Transformer manufacturing:Measuring the transformr's parameters include rated capacity,current ,voltage ,frequency,temperture-rise and noise and so on.